Complete Lab Solution Provider

Diagnostics Equipments

A correct diagnosis leads to correct treatment. Our diagnostic tools help you to help others. We have a wide range of diagnostic equipment and products including stethoscopes and sphygmomanometer.

Clinical Chemistry

Features

Semi-automated Clinical Chemistry analyser

  • End-point, kinetic, fixed time, absorbance
  • Upto 112 tests can be programmed
  • Reaction curve and QC graph print-out
  • Touch screen, large LCD display
  • All-in-one optical system, high reliability and anti-interference
Semi-automated Clinical Chemistry Analyser
Semi-automated Clinical Chemistry Analyser

Technical Specifications

LIGHT SOURCE Quartz-halogen lamp 12V/20W
WAVELENGTH RANGE
  • Automatic by 8 positions filter-wheel
  • 7 standard filters: 340nm, 405nm, 492nm, 510nm, 546nm, 578nm, 630nm
  • 1 position free for optional filter
  • Half bandwidth <8nm
  • Stray light : <1.0% at 340nm
PHOTOMETRIC RANGE
  • 0.0000 to 3.0000 ABS
  • Resolution : 0.0001 ABS
  • Stability : 0.002 A/hour
FLOWCELL
  • Stainless steel with quartz window
  • Measuring volume 32 μL
  • Optical path 10mm
  • Aspiration volume programmable : 200~2000μL
  • Carryover <1.0%
ANALYSIS METHOD
  • End point, with or without reagent blank,
  • End point, with sample blank, with or without reagent blank
  • Kinetic, with or without linearity check
  • Two-point kinetic /fixed time, with or without reagent blank
  • Absorbance
  • Turbidimetry
  • Linear and non-linear calibration
PARAMETER SETTINGS
  • Method
  • Wavelength
  • Temperature
  • Reagent blank y/n
  • Sample blank y/n
  • Lag time
  • Measurement time
  • Reaction time
  • Absorbance limit
  • Aspiration volume
  • Standards
  • Linearity check
  • Unit for results
MEMORY
  • 112 test profiles
  • 3200 sample results
TEMPERATURE CONTROL By means of Peltier elements 25°C, 30°C, 37°C ±0.1°C
INPUT Touch screen
DISPLAY Large LCD display
PRINT Built-in thermal recorder
INTERFACE RS232 serial port
OPERATING ENVIRONMENT Widal Slide
DIMENSION 420mm(H) x 380mm(W) x 170mm(D)
WEIGHT 8.0 kg

Immunology

Features

Microplate (Elisa) Reader

  • 8-Channel optical measuring system
  • Optional single or double wavelength analysis
  • Extensive onboard data analysis
  • Variable speeds linear shaking
  • Cut off and call criteria
  • Large storage for 2500 results
  • Touch screen, large LCD display
Elisa Microplate Reader

Electrolytes

Features

  • Compact, economical easy-to-use
  • Excellent precision and reliability
  • Long life, high performance, maintenance-free electrodes
  • Automatic sampling, Priming, rising and calibration
  • Touch-screen, large LCD display
  • Internal Thermal Printer
  • Auto sampler optional
  • Stanby mode
  • Visual Alarms for reagent inventory management
Electrolyte Analyzer

Specification

  Measuring Range Reproducibility(CV%)
K+ 0.50~15.00 mmol/L <1.0%
Na+ 30.0~200.0 mmol/L <1.0%
Cl+ 30.0~200.0 mmol/L <1.0%
Ca2+ 0.10~5.00 mmol/L <2.0%
pH 7.00~9.00 (unit) <1.0%
Li+ 0.30~3.00 mmol/L <3.0%
Principle Direct measurement by lon selective Electrode (ISE)
Sample Whole blood, serum, plasma, diluted urine
Sample volume 150 ul
Throughput up to 60 samples/h
Data storage up to 500 patient results
Calibration Automatic or On-demand
Input Touch-screen
Display Large LCD with backlight
Output Internal thermal recorder, RS-232 serial port
Ambient conditions
  • Temperature : 100C~300C
  • Relative humidity : 20%~85%
  • non-condensing environment
Input voltage AC 220V/110V + 10%, 50/60Hz
Power consumption 60W
Dimension 440mm X 380mm X 350mm (H x W x D)
Weight
  • Main unit - 10 kg
  • Auto sampler(option) - 1.5 kg

Options

iONS F K+ / Na+ / Cl+
iONS A K+ / Na+
iONS B K+ / Na+ / Cl+ / HCO3+ /AG
iONS C K+ / Na+ / Cl+ / Ca2+ / pH
iONS D K+ / Na+ / Cl+ / Ca2+ / pH / HCO3+ / AG
iONS E K+ / Na+ / Cl+ / Li+

Haematology

Features

3-part WBC Diff Hematology analyser

  • 22 parameters including WBC, LYM, MID, GRA, LYM%, MID%, GRA%, RBC, MCV, HCT, HGB, MCH, MCHC, PLT, MPV, RDW-SD, RDW-CV, PCT,PDW-SD, PDW-CV, P-LCR, P-LCC
  • Open and closed tube sampling with automatic sample rotor and Cap Piercing
  • Throughput of 60 tests / hour
  • 3 separate chamber for primary mixing, RBC and WBC counting
  • High quality cyanide free reagents imported from Europe
  • 6 QC Level, 16 and 64-day Levey-Jennings charts, separate QC database
  • Data storage capacity of 10000 results with RBC, PLT, WBC 3-part histogram
  • Optional external barcode reader and keyboard
  • High-contrast, backlit, color graphics LCD
  • Capability of using any external printer via a printer box
  • US-FDA approved

Hematology diagnosis is not a matter of compromise. iCount3CP combines reliability and accuracy with computer-enhanced benefits of handling. iCount3CP is a heavy duty compact analyzer offering an optimal solution for hospitals, clinics and practices, which require high quality and fast CBC and 3-part WBC differential results. Our Hematology analyzers bring the convenience and accuracy of the reference laboratory right into your practice, offering maximum value at low running costs.

Hematology Analyser
Hematology Analyzer
3-part WBC Diff Hematology Analyser

High Performance

  • iCount3CP provides 20-parameters, a complete CBC including a 3 part WBC differential
  • High throughput of 60 samples per hour, results within 60 seconds
  • The fluidic system is automatically cleaned from dust particles when turning on the analyzer. High voltage pulses after each measuring cycle keep the apertures free from clogging. The instrument automatically cleans the sampling tip inside and outside after blood aspiration to minimize the risk of carryover and infection.
Hematology Analyser Performance
Hematology Analyzer Performance

Safe

  • Cap piercing feature to enable accurate sampling from closed tubes thus minimising biohazard risks.

Ease of use

  • Color LCD, the large display allows rapid and accurate patient data entry and monitoring of the results with large histograms
  • Sample rotor, ensuring safe and easy sampling
  • The instrument features a sophisticated but easy-to-use, logically constructed multilingual operating menu. It provides 6-level QC, L-J graphs and self-diagnostic functions to let you monitor reliability and accuracy
  • All iCount3CP models can be interfaced with your host computer for further processing of the measured data. Results can also be retrieved on the built-in roll paper printer

Reliable and efficient

  • iCount3CP is almost maintenance free resulting in minimal disruption of operation
  • iCount analyzers are small and light. Their compact size makes the instruments ideal for use in smaller clinics requiring minimum desktop space
  • Clinical environment by utilizing industry standard electronic and mechanic components
Reliable Hematology Analyzer
Reliable Hematology Analyser
Efficient Hematology Analyzer

Technical Specifications

Sample method Closed and open tube sampling with automatic sample rotor
Parameters 20 parameters, including 3-part WBC differential: WBC,LYM#, MID#, GRA#, LYM%, MID%, GRA% RBC, MCV, HCT, HGB, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PCT, PDW-CV, PDW-SD
Chambers 3 chambers for diluting whole blood and counting; 1:MIX, 1:RBC, 1:WBC
Reagent system Isotonic Diluent, Lyse, Cleaner
Aperture diameter 80 ìm (RBC/PLT), 100 ìm (WBC)
Throughput 60 tests/hour
Sample types Human(general), male, female, baby, toddler and child (built-in reference ranges)
Clog prevention High-voltage pulse on aperture in each analysis cycle; chemical cleaning; high pressure backflush of aperture with Cleaner reagent.
Cleaning procedure High-voltage burst of the aperture, high-pressure back-flush, chemical cleaning of the aperture using Cleaner reagent.
Quality control 6 QC levels, QC parameters include: mean, ± range, SD and CV for all measured and calculated parameters, 16- and 64-day Levey-Jennings charts, separate QC database.
Calibration 1 or 3-measurement automatic and manual (factors) calibration of WBC, HGB, RBC, PLT, MCV, RDW and MPV absolute. Independent calibration of pre-diluted mode.
Multi-user feature (advanced feature) 3-level multi-user operation with selective privilege levels, user identification with ID and password.
User interface Easy-to-use, menu driven user interface with 6 software buttons (with graphic icons), 6 hardware function buttons, cursor and numeric keys.
Languages available English, German, Hungarian, Arabic, Bulgarian, French, Greek, Indonesian, Polish, Portuguese, Romanian, Russian, Slovakian, Spanish, Turkish, Vietnamese
Data capacity Maximum 5000 results with RBC,PLT, WBC 3-part histogram
Host computer interface USB B port or RS-232 serial link.
Data back-up method USB mass storage device; Lab data management software.
Software upgrade method USB A port using USB mass storage device
Printer interface USB with support for HP printers, color and monochrome printout.
Built-in printer "Easy Paper Operation" thermal printer module, full report with histograms
Display 320x240 -dots, high-contrast, backlit, color graphics LCD
Keypad 29 foil keys + separate START button, red/green/orange machine state light.
External keyboard Standard PS/2 compatible or USB
Power requirement 12VDC, 6A, 72W max. operating power.
Power supply unit External, auto-ranging power unit for 100-120 or 200-240 VAC, 50-60Hz.
Operating temperature 59-86 °F (15-30 °C). Optimal temperature is 77 °F (25 °C).
Dimensions (W x D x H) 350 X 385 X490 mm
Net weight 15 kg.

Accurate & Reliable Results

  • 21 parameters and RBC, WBC, PLT histograms
  • Utilize digital filtering, blood cell - overlap calibration, fitting curve, floating threshold technology etc. to enhance the accuracy and reliability of results
  • High quality syringe pump with high quantitative precision

Perfect QC Function

  • L-J, X, X-B 3 levels of controls for daily QC with Levey-Jennings charts

Easy Maintenance

  • Zap and backflush cleaning system to prevent apertures blocking
  • Special boot program to rinse pipelines and probe automatically
  • Only 3 reagents involving test

Large Storage

  • 10,000 results with 3 histograms to satisfy customers' requirements

User Friendly Design

  • Cyanide-free hemolytic reagent for HGB detection, safety and environment pollution free
  • Eiectric hydraulic separation structure design
  • Automatic reagents remaining detection
  • USB and RS232 interfaces, easy for backup
  • Multiple languages
  • LIS connection

Easy Operation

  • Large color LCD with high resolution.
  • Automatic sampling, mixing and analyzing
  • Equipped with barcode reader
  • Abundant prompt information
  • Abnormal value flag and reference ranges modified as the local requirements
  • Automatic dormancy setting
Haematology ICount3 TS

Technical Specifications

Parameters WBC, RBC, HGB, MCV, MCH, MCHC, HCT,PLT, NEUT#, MXD#, LYM#, NEUT%,MXD%,LYM%,R DW-CV, ROW-SO, POW, MPV,PCT, P-LCR, P-LCC
Histogram WBC, RBC, PLT
Principles WBC, RBC, PLT : electrical impedance HGB: Cyanide-free colorimetry
Cross Contamination WBC, RBC, HGB < 0.5%, PLT < 1%
Aperture Diameter WBC 100 μm, RBC/PLT 70 μm
Sample Consumption Whole blood 6μL,Pre-diluted blood 20μL
Throughput 60 samples/hour
Display 10.1 inch touch screen, Resolution: 1024 X 600
Reagent Detergent, Diluents, BCC-3600 Lyse
Multiply QC methods L-J, X:12QC files,30 results/file.X-B:1file, 150 results/file
Calibration Manual calibration, automatic calibration,fresh blood calibration
Counting Mode Whole blood and pre-diluted blood
Input/ Output Build in thermal printer,RS232,USB
Environment Requirement Ambient temperature 18°C-30°C,Relative humidity: ≤ 75%
Power Supply 100-240 VAC 50/60HZ
Dimension (mm) 430(L) X 395(W) X 432(H)
Weight 25 Kg

3-part WBC Diff Hematology analyser

  • Throughput of 60 tests / hour
  • Double channel plus unique hemoglobin test system
  • Low sample consumption
  • Mouse and keyboard operation
  • Automatic dilution, mixing, rinsing and clog clearing
  • Automatic sample probe cleaning
  • Large storage capacity of upto 10000 samples plus histograms
  • Internal thermal printer or optional external printer
  • RS232 interface & PC connectivity
  • 3-part differentiation of WBC, 20 parameters and 3 colour histograms
  • Volume measurement by time
  • Advanced valve technology, long life
  • RS232 interface, PC connectivity
  • Double channel counter
Haematology iCount 3+
Haematology analyser iCount 3+

Features

  • 3-part differentiation of WBC, up to 60 samples per hour
  • Electrical resistance for counting and SFT method for Hemoglobin
  • Low sample consumption: Whole Blood 9.8uL, prediluted 20uL
  • 8.4" colour TFT screen
  • Windows interface, all testing parameters displayed simultaneously
  • Mouse and keyboard operation
  • Automatic dilution, mixing, rinsing and clog clearing
  • Automatic sample probe cleaning (inside and outside)
  • Large storage capacity : up to 10,000 samples plus 3 histograms
  • Internal thermal printer or optional external printer
  • RS232 interface & PC connectivity

Main Technical Specifications

Methodology Electrical resistance for counting WBC, RBC and PLT and SFT method for hemoglobin
Parameter 3-part differentiation of WBC; 20 parameters and 3 colour Histograms (WBC, RBC, PLT)
Work mode Double channel + unique Hemoglobin test system
Sample volume 9.8 uL for venous and capillary whole blood mode, 20 uL for prediluted mode
Throughput 60 samples per hour, operatable 24 hours a day, auto sleep and wake up functions
Storage up to 10,000 samples result including histograms can be stored.
Operating language English
Quality Control X-B, L-J, X, SD, CV %
Reference value setting Male, Female, Children, Neonate
Input / Output RS232, parallel printer and keyboard
Print Graphic thermal printer with various printing formats, optional external printer
Temperature 18°C - 30°C,
Humidity 10 - 90%
Power supply 220 V + 22 VAC, 50 + 1Hz
Dimension 33 Cm (L) * 38 cm (W) * 43 CM (H)
Weight 20 KG

Precision

Parameters Linear range CV %
WBC (10 9/L) 0.0 - 99.9 < 2 %
RBC (1012/L) 0.0 - 9.99 < 1.5 %
MCV (fL) 4 - 150 < 0.5 %
PLT (10 9/L) 0 - 999 < 4.0 %
HGB (g/L) 0.0 - 300.0 < 1.5 %

Parameters

WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, L-PCR

3-Histograms

WBC, RBC and PLT



iCount5 is one of the high-end models of iCount Hematology Analyzers range. The ‘iCount5’ offers an optimal solution for hospitals, clinics and practices, which require a high throughput 24 parameter analyzer with laser based optical measuring technology for precise and accurate 5-part differential results for human samples. Our Hematology analyzers bring the convenience and accuracy of the reference laboratory right into your practice, offering maximum value at low running costs.

Haematology iCount 5
Haematology Analyzers iCount 5
Haematology Analyser iCount 5

High performance

  • Complete 24-parameter CBC profile including the optical determination of the 5 part WBC differential count
  • 60 samples per hour throughput (single runs or work order)
  • Auto-sampler with integrated bar code reader available
  • Diagnostic flagging system
  • Intelligent software is used for determining the different white blood cell populations

Ease of use

  • Color touch-screen, allowing fast and efficient work and monitoring of the results with large histograms and scattergrams
  • Sophisticated operating menu, the instrument features an easy-to-use,logically constructed multilingual operating menu. It provides 6-level QC, L-J graphs and self-diagnostic functions to let you monitor reliability and accuracy
  • Integrated PC enabling easy connection to any (LIS) system or printer
  • Reporting on any Windows compatible printer

Reliable and efficient

  • The optical measurement technology utilizes laser diode ensuring a long lifetime and precise results with the special, high-tech flow cuvette
  • iCount5 requires minimal maintenance, resulting in minimal disruption of operation
  • iCount analyzers are kept small and light. Their compact size makes the instruments ideal for use in small to medium sized clinics requiring minimum desktop space
  • Precise and reliable 5-part hematology profiles are guaranteed even in the most demanding clinical environment by utilizing industry standard electronic and mechanic components

Technical Specifications

Sample volume Closed-, and Open-mode: 100 μl
Sample type Human whole blood (K-EDTA anticoagulant)
Tube Identification By means of the front panel keyboard (enter ID) By means of the barcode labels (manual and/or auto-sampler)
Sampling method Ceramic shear valve with 3 separated primary loops
Measured parameters CBC+5 DIFF mode ( 24 parameters): WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW-CV, RDW-SD, HGB,MCH, MCHC, PLT, PCT, MPV, PDW-CV, PDW-SD CBC mode (12 parameters): WBC, RBC, HCT, MCV, RDW, HGB, MCH, MCHC, PLT, PCT, MPV, PDW
Throughput 60 tests/hour
Measurement method
  • Volumetric impedance change for WBC, RBC, PLT. Spectrophotometry for HGB
  • Light scattering 4-diff measurement: LYM, MON, NEU, EOS
  • Light scattering BASO measurement
Aperture diameter WBC: 100 μm, RBC/PLT: 80 μm
Aperture length WBC: 100 ìm, RBC/PLT: 80 ìm
HGB measurement Light source : green LED with 540 nm wavelength. Detector: light to frequency converter
Optical measurement
    Light source : semiconductor laser diode with 650 nm wavelength and 10mW
  • (Class IIIB laser module if the protective housing is closed)
  • Quartz flow cell with hydro-dynamic focusing
  • Detector: fiber optic coupled PIN Si photodiodes Internal safety interlock
Auto-alignment system
  • Optional. Horizontal and vertical calibration of laser beam path
  • Coarse calibration: with blood
  • Fine calibration: with calibration material (Polystyrene micro particle or Polystyrene microsphere, 7μm)
Reagents
  • Diatro • Dil-DIFF (20 liter)
  • Diatro • Lyse-5P (5 liter)
  • Diatro • Diff-5P (5 liter)
  • Diatro • Hypocleaner CC (100 ml) (Emergency cleaner)
Dilution ratios
  • WBC/BAS 1: 228
  • RBC/PLT 1: 32.000
  • 4 DIFF 1: 250
Sheath fluid Diluent
Control material D-Check 3P, Manufacturer: R&D Systems
Quality Control 16- and 64-day Levey-Jennings charts, separate QC database (6 level).
Flagging Pathological (diagnostic) flags. Lab limits (normal ranges). Reagents alert (3 measurement prealert-online reagent replacement) Instrument alerts, internal puffer for reagents
Calibration Manual and SW supported automatic mode
Languages available English menu and support for other languages
Software upgrade Via USB
Data storage capacity 100.000 records including flags, scatter- and histograms
Data processing VIA C7 1.8 GHz processor
Data store Embedded XP
Display 800 x 600 color graphic LCD, portrait layout
External printing Via USB port, any Windows compatible printer
External keyboard Via PS/2 or USB
Bar-Code reader Optional Manual bar-code reader via USB Built in Bar-Code in the Auto-samplerB
Peripheral ports USB (2.0) 4pc., Ethernet, PS/2
Power requirements
  • Power supply input: from 90-135Vac to 180-265Vac; 47Hz to 63Hz
  • Power supply input current: <10A @ 115Vac; <5A @ 230Vac
  • 0 0 Power Consumption: maximum 350 VA and15-35 C (59-98 F);

Features

Accurate & Reliable Results

  • 21 parameters and RBC, WBC, PLT histograms
  • Utilize digital filtering, blood cell - overlap calibration, fitting curve, floating threshold technology etc. to enhance the accuracy and reliability of results
  • High quality syringe pump with high quantitative precision

Perfect QC Function

  • L-J, X, X-B 3 levels of controls for daily QC with Levey-Jennings charts

Easy Maintenance

  • Zap and backflush cleaning system to prevent apertures blocking
  • Special boot program to rinse pipelines and probe automatically
  • Only 3 reagents involving test

Large Storage

  • 10,000 results with 3 histograms to satisfy customers' requirements

User Friendly Design

  • Cyanide-free hemolytic reagent for HGB detection, safety and environment pollution free
  • Eiectric hydraulic separation structure design
  • Automatic reagents remaining detection
  • USB and RS232 interfaces, easy for backup
  • Multiple languages
  • LIS connection

Easy Operation

  • Large color LCD with high resolution.
  • Automatic sampling, mixing and analyzing
  • Equipped with barcode reader
  • Abundant prompt information
  • Abnormal value flag and reference ranges modified as the local requirements
  • Automatic dormancy setting
Haematology ICount3 TS

Technical Specifications

Parameters WBC, RBC, HGB, MCV, MCH, MCHC, HCT,PLT, NEUT#, MXD#, LYM#, NEUT%,MXD%,LYM%,R DW-CV, ROW-SO, POW, MPV,PCT, P-LCR, P-LCC
Histogram WBC, RBC, PLT
Principles WBC, RBC, PLT : electrical impedance HGB: Cyanide-free colorimetry
Cross Contamination WBC, RBC, HGB < 0.5%, PLT < 1%
Aperture Diameter WBC 100 μm, RBC/PLT 70 μm
Sample Consumption Whole blood 6μL,Pre-diluted blood 20μL
Throughput 60 samples/hour
Display 10.1 inch touch screen, Resolution: 1024 X 600
Reagent Detergent, Diluents, BCC-3600 Lyse
Multiply QC methods L-J, X:12QC files,30 results/file.X-B:1file, 150 results/file
Calibration Manual calibration, automatic calibration,fresh blood calibration
Counting Mode Whole blood and pre-diluted blood
Input/ Output Build in thermal printer,RS232,USB
Environment Requirement Ambient temperature 18°C-30°C,Relative humidity: ≤ 75%
Power Supply 100-240 VAC 50/60HZ
Dimension (mm) 430(L) X 395(W) X 432(H)
Weight 25 Kg

POCT

Test Procedure

Smart is Versatile

  • The Diazyme SMART is a multiparameter compact instrument with a constantly expanding range of applications
  • Barcode reader
  • Able to connect to a PC and to HIS or LIM

Smart is Reliable

  • An ideal combination of simplicity and analytical performance
  • Accuracy and precision that up to now was only achieved by large-scale laboratory systems
  • Automated integrity check with each test
  • FDA cleared, CE compliant
  • One year warranty

Smart is Simple

  • Touch Screen
  • RFID Card
  • Quick data entry with icons
  • Simple data transfer to a printer or host (Seiko DPU-414 thermal printer recommended)
  • Identifies lot expiration date
  • Indicates the number of tests remaining
  • Permits updates of the testing procedures without changing the instruments’s software
  • Weight: 3.4 kg / 7.7 lbs
  • Dimensions: 24 x 14.5 x 14 cm / 9.4 x 5.7 x 5.5 in.
Poct Instruments
Parameter Method Sample Material Assay Time Sample Volume Precision Assay Range
HbA1c Enzymatic Whole Blood 7 min 20 μl CV ≤ 3% 4.0% - 12.0% HbA1c
Cystatin C Immunoturbidimetric Whole Blood 10 min 20 μl CV < 10% 0.30 - 7.65 mg/L
Homocysteine Enzymatic Serum/Plasma 13 min 20 μl CV < 8% 3.0 - 50.0 μmol/L
hsCRP Immunoturbidimetric Whole Blood 4 min 20 μl CV < 10% 0.47 - 28.0 mg/L
GSP Enzymatic Serum/Plasma 10 min 40 μl CV < 6% 70.0 - 126.9 μmol/L
PCT Immunoturbidimetric Serum/Plasma 10 min 50 μl CV < 8% 0.19 - 12.00 ng/mL
Smart 700 - 340
HbA1c 510(k) Cleared
Homocysteine 510(k) Cleared
Cystatin C 510(k) Cleared
hsCRP 510(k) Cleared
Procalcitonin (PCT)*
Smart 700 - 546
HbA1c 510(k) Cleared
Cystatin C 510(k) Cleared
hsCRP 510(k) Cleared
Glycated Serum Protein (GSP) 510(k) Cleared
Procalcitonin (PCT)*

A Rapid, Reliable Testing Platform With A Unique Assay Display

*USA: For Research Use Only

Urine Chemistry